T1 Over IP

IP•Tube for T1 Circuit Extension over IP

Extend T1 voice and data circuits over Ethernet and IP

Keep T1-connected voice and data equipment in service as you move the transport network to Ethernet and IP. Engage IP-Tube equipment encapsulates full or fractional T1 circuits into IP packets and reconstructs the T1 connection at the remote endpoint.

Applications include PBX and channel-bank extension, T1 data transport, and legacy cellular backhaul. Start with the number of T1 interfaces, the circuit's framing and signaling, and the timing, voice, and management requirements of your installation.

Choose a model  |  Plan your T1 connection  |  T1 over IP FAQs

Choose the right T1 over IP model

IP-Tube DLT1

For one or two active T1 interfaces. Choose DLT1 for full or fractional T1 voice and data transport when a smaller port count fits the application. Specify the active interfaces, compression, power, and redundancy options required.

IP-Tube DLT1-ECAN

T1 over IP with echo cancellation for one or two active interfaces. Consider DLT1-ECAN for voice circuits that need far-end echo control. Specify echo-cancellation hardware when ordering; compression is a separate option.

IP-Tube GT1

For one to four active T1 interfaces. GT1 suits sites carrying several circuits with independent configuration requirements. Additional T1 ports can be enabled through licensing as needs grow. Select the required transport and power options.

IP-Tube CEP GT1

For one to four T1 interfaces with separate secure management. CEP separates management and data processing and provides a dedicated management Ethernet interface. Choose it when controlled administrative access is part of the network design.

IP-Tube GT1-ECAN

T1 over IP with integrated echo cancellation across four T1 interfaces. Choose GT1-ECAN for multiple voice circuits requiring echo control. Confirm channel configuration, optional compression, and the network's delay characteristics for the application.

IP-Tube G4 T1

For one to four T1 interfaces with Ethernet switching options. G4 offers an optional integrated five-port switch with traffic prioritization, VLAN, and rate-limiting features. Select the switch, timing, and protection options for your deployment.

Compare T1 over IP models

Product

TDM Ports

Data Ethernet Ports

Data Compression- Comp

Echo Cancellation- Ecan

Link Protector -LPT

Alternator-ALT

Power Options

CEP Advanced Management

1 to 2 T1

2 10/100

Option

No

Option

Option

Option

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

No

1 to 2 T1

2 10/100

Option

Yes

Option

Option

Option

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

No

1 to 4 T1

2 10/100

Option

No

Option

Option

Option

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

No

1 to 4 T1

2 10/100

Option

Confirm configuration

Option

Option

Option

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

4 T1

2 10/100

Option

Yes

Option

Option

Option

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

No

1 to 4 T1

1 × 10/100; 5-port switch option

Option

No

Option; requires switch

N/A

Confirm configuration

N/A

Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

No

Specify the active T1 ports and required options when ordering. CEP includes a separate management Ethernet interface in addition to the data ports listed. The G4 five-port switch is optional; its LAN Protector configuration requires the switch option. Confirm configuration where indicated.

Compare T1 over IP models

IP-Tube DLT1 T1-over-IP unit

TDM Ports: 1 to 2 T1

Data Ethernet Ports: 2 10/100

Data Compression -Comp: Option

Echo Cancellation -Ecan: No

LAN Protector (-PRO): Option

Link Protector -LPT: Option

Alternator (-ALT): Option

Chassis Slot Card Version Available: Yes

Power Options: Standard AC to DC Adapter, -48VDC, +24 Wired DC, w/ or w/o Redundant

CEP Advanced Management: No

Specify the active T1 ports and required options when ordering. CEP includes a separate management Ethernet interface in addition to the data ports listed. The G4 five-port switch is optional; its LAN Protector configuration requires the switch option. Confirm configuration where indicated.

How T1 circuit emulation works

A typical point-to-point deployment uses compatible IP-Tube equipment at both ends of the IP network. The local unit packetizes the T1 circuit; the remote unit reconstructs the signal for the connected T1 equipment.

Confirm the clock source and configure framing, line coding, and channel assignments at both ends. Packet size and buffering must suit the network's delay variation and the application's latency needs.

Before choosing a model

  • Circuit: T1 interface count, full or fractional service, channel assignments, ESF or D4 framing, B8ZS or AMI coding, and signaling.
  • Timing and network: clock source, available bandwidth, latency, jitter, and traffic prioritization.
  • Resilience: backup IP paths, T1-circuit protection, power redundancy, and mounting.
  • Voice and security: echo cancellation, optional compression, management controls, and payload-encryption requirements.

T1 over IP deployment examples

Site-to-site T1 extension over IP

An IP-Tube GT1 at each end transports the T1 circuit between sites over an IP network while keeping the existing T1-connected equipment in service.

Select the diagram to enlarge.

Point-to-multipoint T1 connectivity

This example uses four enabled T1 ports on the central GT1. Each port carries an independent T1 circuit to a different remote GT1, while the Ethernet link carries the separate packet streams. Match each circuit's timing and network settings to the application.

Select the diagram to enlarge.

Product Options

fa fa-diamond

Lossless Data Compression

The optional lossless compression feature reduces repeated transmission of idle and redundant data within T1 voice circuits. Bandwidth savings depend on the traffic pattern and configuration.

Specify a supported compression configuration when ordering. Plan network capacity around the expected traffic, packet overhead, and any redundant streams.

fa fa-object-ungroup

Echo Cancellation

ECAN models include digital signal processing for far-end voice echo cancellation. This is useful when the voice connection needs echo control across the complete circuit path.

Echo cancellation and jitter buffering serve different purposes. Select the required ECAN hardware and configure packet buffering for the network's delay variation and the application's latency requirements.

fa fa-html5

LAN Protector -PRO

The Protector option provides for automatic protection of the T1 circuit over independent IP packet routes. After conversion of the T1 circuit into IP packets, two identical packet streams are created. These duplicate packet streams are used to provide redundant IP connectivity to the remote location in either Always-On* or On-Demand* switch over modes.

The need to Protect Critical Communications is in high demand for the following applications:

•  Public Safety Network Redundancy for Police, Fire and Medical
•  Auto Recovery for Military Communication
•  Delivering on Service Level Agreements
•  Resilient Cellular Backhaul

In Always-On mode, the Protector sends duplicate T1 packet streams over two IP paths. The remote unit monitors the incoming streams and selects packets to reconstruct the T1 circuit. Design and configure both paths for the required timing and protection behavior.

fa fa-diamond

Link Protector -LPT

The optional Link Protector provides a T1-over-IP backup path for an existing T1 circuit. It supports automatic protection switching when the configured failure conditions are met.

Confirm the T1 interface arrangement, failure-detection criteria, and backup IP transport as part of the circuit-protection design.

fa fa-object-ungroup

CEP Management

CEP uses separate processors for management and data transport, with a dedicated management Ethernet interface. SSH and SNMPv3 protect management access, with centralized authentication through TACACS+ or RADIUS.

Syslog supports administrative and user activity records. For encryption of the transported T1 payload, review the BlackTube T1 product.

• Administrative policies for adding, removing, disabling and renaming authorized users; limiting user access to assigned commands; and enabling only desired port numbers.

• User authentication directly or in conjunction with TACACS+ or RADIUS servers including RSA SecureID support for two factor trusted compliance.

• An SSH command interface encrypting management traffic with powerful 256 bit symmetric keys and NIST based passwords.

• Support of the SNMPv3 protocol for secure connectivity to SNMP element managers.

• In addition, administrative accounting data can be reported to syslog servers with accurate timestamps provided by an NTP source.

fa fa-object-ungroup

Alternator -ALT

The optional Alternator sends packetized T1 traffic alternately across two Ethernet/IP paths. This distributes the circuit's packet stream across the available connections.

Confirm model support and the required network interfaces, and account for bandwidth and delay differences between the paths.

Rack Mountable CHASSIS for Engage Modules

Compact Design

The Chassis is designed to accommodate from 1 to 15 Networking, Telecommunication or Encryption modules from Engage Communication IP•Tube, IP•Express, Black•Bond and Black•Door product lines. 

Dimensions

• Height: 5U (8.75 in, 222 mm)
• Width: 19/23 inches, 480/580 mm
• Depth: 12 inches, 300 mm

The CHUB CHASSIS

Engage modular rack-mount chassis for compatible T1 modules

Power Redundancy

Power slot accommodates 2 Hot Swappable Commercial, Industrial or Military Grade Off The Shelf 1U Chassis Power modules that are available as Universal 90/240 VAC 50/60 Hz, Isolated -48 VDC, or 12 to 30 VDC.

Suitable for ETSI or ANSI installations

Compactly concentrate up to 60 T1 or E1 circuits that are extended over packetized networks

Related TDM circuit emulation solutions

Transparent operation maintains the proprietary signaling required to support PBX features such as call conferencing, call forwarding, caller ID and SS7

Legacy phone equipment investment is preserved

Available with Integrated Echo Cancellation and Lossless Data Compression

Encapsulates a full T3 circuit into IP packets

T3 Over IP connections provide for the interconnection of PBXs, Cellular equipment and Telecom Switches via LANs, WANs, MANs, IP Satellite, xDSL, Cable and Wireless Ethernet

Encapsulates a full E3 circuit into IP packets

E3 Over IP connections provide for the interconnection of PBXs, Cellular equipment and Telecom Switches via LANs, WANs, MANs, IP Satellite, xDSL, Cable and Wireless Ethernet

Core Features

Years of Product Innovation in the Networking, Security and Telecommunications Fields

Assured Delivery Protocol

Packet out of sequence detection and re-sequencing, duplicate skipping and lost packet retransmission with configured delay

Protector OPTION

The optional Protector carries T1 packets over redundant IP paths. Configure Always-On operation or failover criteria with the network interfaces and options required by the selected model.

Power Redundancy OPTION

Available as WIREDC, -48VDC or Standard Power Supply Modules... Protect your networks operation with Redundant Power.

Why Choose Us?

Since 1989, Engage has developed innovative products and solutions that help organizations across the globe deploy and operate cost-effective and reliable communications, and meet their data security needs.

Core Features

Years of Product Innovation in the Networking, Security and Telecommunications Fields

Assured Delivery Protocol

Packet out of sequence detection and re-sequencing, duplicate skipping and lost packet retransmission with configured delay

Protector OPTION

The optional Protector carries T1 packets over redundant IP paths. Configure Always-On operation or failover criteria with the network interfaces and options required by the selected model.

Power Redundancy OPTION

Available as WIREDC, -48VDC or Standard Power Supply Modules... Protect your networks operation with Redundant Power.

Why Choose Us?

Since 1989, Engage has developed innovative products and solutions that help organizations across the globe deploy and operate cost-effective and reliable communications, and meet their data security needs.

T1 over IP frequently asked questions

Can I retain a PBX, channel bank, or PRI interface?

T1 circuit emulation can carry the framing and signaling needed by compatible T1-connected equipment. Confirm the signaling, channel assignments, and clocking of the actual PBX, channel bank, or telecom equipment with Engage. See PBX over IP applications.

Does this convert a T1 or PRI service to SIP?

IP-Tube extends a T1 circuit across an IP network and presents T1 at the remote endpoint. Converting voice calls to SIP or replacing carrier telephone service requires a separate service and gateway design. For a carrier-retirement project, plan both circuit endpoints and the replacement transport together.

How much IP bandwidth does a T1 connection need?

Size the connection for the number of circuits, selected channels, packet size, and network overhead. Allow for any duplicate streams used for redundancy. Optional lossless compression can reduce bandwidth when traffic contains idle or repeated data; the saving depends on the traffic.

How do timing and network jitter affect the connection?

The remote T1 needs a suitable clock source. Buffering compensates for variation in packet arrival time, but also adds delay. Match the clocking and buffer settings to the circuit and measured network behavior, especially for voice and timing-sensitive applications.

When should I choose an ECAN model?

Choose an ECAN model when the voice application needs far-end echo cancellation. Echo cancellation addresses voice echo; packet buffering and network design address delay variation. Specify the required echo-cancellation hardware and number of T1 interfaces when ordering.

Does CEP management security encrypt the T1 payload?

CEP secures management access and separates management processing from the data plane. For encrypted T1 transport, review BlackTube T1 and confirm the required security configuration.

Get help planning your T1 over IP connection

Send us the connected equipment, number of T1 circuits, full or fractional channel requirements, clocking source, and a brief network layout. Engage can help select the model, voice options, power configuration, and protection features for your application.

Engage Communication
9565 Soquel Drive. Aptos, CA 95003
sales@engageinc.com
support@engageinc.com



Telephone: 1-831-688-1021
Toll Free : 1-877-ENGAGE4
 
 
Designed, Fabricated, and Assembled
in America 
Supported Worldwide