Example 9:

IP•Tube RS530 Video

Scenario: This sample configuration details the interconnection of a synchronous serial Video Encoder to a Video Decoder via IPTubeRS530s that are providing smooth clocking at a rate of 1.536 Megabits per second. The IPTube's Ethernet interconnection has a committed information rate that is much greater than the IPTube's maximum data rate. Therefore the Ethernet bandwidth available is relatively unlimited.
The Tube Clock on one of the IPTubeRS530s need to be set to Internal and the other to PLL. The SCRCLOCK will be set to run at the same speed as the SCTCLOCK without gapping so that buffering of packets is required and the Frames Per Packet is set to the maximum for maximum efficiency.
For this example, the user will select Frames-Per-Packet = 20. With this TUBE FPP setting, the Overhead Table in Chapter 6 indicates an approximate 3.4% (ratio is 1.034) overhead. IPTube Ethernet Data rate is 1.034 times 1.536 Mbps.

  IP•Tube T1

# Config File Name
# IPT530_video.txt
# Command Line Listing
Host Name IPTube-530
IP Default-router
Interface E1
# IP Address of this IP•Tube
IP Address 192.168.1.1/24
Interface S1
Type RS-530
SCR Normal
SCT Normal
Protocol IPTube
Tube On
# IP Address of the Remote IP•Tube
Tube Address 192.168.1.2
Tube TOS 0x08
Tube FPP 20
Tube Clock Internal
Tube SCRCLOCK MODE NX64K
Tube SCRCLOCK FACTOR 24
Tube SCTCLOCK MODE NX64K
Tube SCTCLOCK FACTOR 24
Tube Buffer 10
Tube Interval 0
Tube Percentage 100

 
    Privacy | Glossary | Subscribe | Contact Information | News | sales@engageinc.com | © Copyright 1989-2008 Engage Communication, Inc.